DSE8620 MKII Synchronising AMF Load Share Control Module
Metal Mosaic Bistro Patio Set with 2 Folding Chairs – Outdoor Garden Table & Chair Set
DSE 8620 MKII AMF Controller For Sale DSE8620 MKII Synchronising Auto Mains (Utility) Failure Load Share Control Module The DSE8620 MKII represents the latest in complex load sharing & synchronising control technology. Designed to synchronise a single genset with a mains (utility) supply, the DSE8620 MKII control module is packed with multiple features and benefits that are unrivalled across the generator control industry. The controller also has the option to be configured for use as a DSE8610 MKII Auto Start Load Sharing & Synchronising Control Module. When converted for use as a DSE8610 MKII the unit provides generator to generator load share functionality. KEY FEATURES • Comprehensive synchronising & loadsharing capabilities • Built in governor and AVR control • Base load (kW export) control • Positive & negative kVAr export control • Mains (Utility) decoupling protection • Mains (Utility) failure detection • Mains (Utility) power (kW, kV Ar, kV A & pf) monitoring • Mains (Utility) de-coupling protection • Mains (Utility) kW export protection • Peak lopping & shaving functionality • 4-Line back-lit LCD text display • Multiple Display Languages • Five key menu navigation • LCD alarm indication • Heated display option available • Customisable power-up text and images • DSENet® expansion compatibility • Data logging & trending facility • Internal PLC editor • Protections disable feature • Fully configurable via PC using USB, RS232, RS485 & Ethernet communication • Front panel configuration with PIN protection • Power save mode • 3 phase generator sensing and protection • Generator current and power monitoring (kW, kvar, kVA, pf) • kW and kvar overload alarms • Reverse power alarms • Over current protection • Unbalanced load protection • Independent earth fault protection • Breaker control via fascia buttons • Fuel and start outputs configurable when using CAN • 8 configurable DC outputs • 2 configurable volt-free relay outputs • 4 configurable analogue/digital inputs • Built in sensors to support 0 V to 10 V & 4 mA to 20 mA • 12 configurable digital inputs • Configurable 5 stage dummy load and load shedding outputs • CAN, MPU and alternator frequency speed sensing in one variant • Real time clock • Manual and automatic fuel pump control • Engine run-time scheduler • Fuel usage monitor and low fuel level alarms • Simultaneous use of all communication ports • Remote SCADA monitoring via various DSE software applications • MODBUS RTU & TCP support with configurable MODBUS pages for integration into building management systems (BMS) • 3 configurable maintenance alarms • Compatible with a wide range of CAN engines, including tier 4 engine support • Uses DSE Configuration Suite PC Software for simplified configuration KEY BENEFITS • Can be configured for use as a DSE8610 MKII • 132 x 64 pixel ratio display for clarity • Real-time clock provides accurate event logging • Ethernet communication, provides builit in advanced remote monitoring. • Can be integrated into building management systems (BMS) and programmable logic control (PLC) • Increased input and output expansion capability via DSENet® • Licence-free PC software • IP65 rating (with supplied gasket) offers increased resistance to water ingress • Extended internal PLC editor allows user configurable functions to meet specific application requirements. SPECIFICATIONS DC SUPPLY CONTINUOUS VOLTAGE RATING 5 V to 35 V Continuous CRANKING DROPOUTS Able to survive 0 V for 100 mS, providing supply was at least 10 V before dropout and supply recovers to 5 V. This is achieved without the need for internal batteries.LEDs and backlight will not be maintained during cranking. MAXIMUM OPERATING CURRENT 530 mA at 12 V, 280 mA at 24 V MAXIMUM STANDBY CURRENT 320 mA at 12 V, 160 mA at 24 V CHARGE FAIL/EXCITATION RANGE 0 V to 35 V GENERATOR & MAINS (UTILITY) VOLTAGE RANGE 15 V to 415 V AC (Ph to N) 26 V to 719 V AC (Ph to Ph) FREQUENCY RANGE 3.5 Hz to 75 Hz MAGNETIC PICKUP VOLTAGE RANGE /- 0.5 V to 70 V FREQUENCY RANGE 10,000 Hz (max) INPUTS DIGITAL INPUTS A TO L Negative switching ANALOGUE INPUTS A TO D Configurable as: Negative switching digital input 0 V to 10 V sensor 4 mA to 20 mA sensor 0 Ω to 480 Ω sensor OUTPUTS OUTPUT A & B (FUEL & START) 15 A DC at supply voltage OUTPUTS C & D 8 A AC at 250 V AC (Volt-free) AUXILIARY OUTPUTS E to L 2 A DC at supply voltage BUILT IN AVR GOVERNOR CONTROL MINIMUM LOAD IMPEDANCE 500 Ω Fully isolated GAIN VOLTAGE 0 V to 10 V DC Fully isolated OFFSET VOLTAGE 0 V to 10 V DC Fully isolated DIMENSIONS OVERALL 245 mm x 184 mm x 51 mm 9.6” x 7.2” x 2.0” PANEL CUT-OUT 220 mm x 160 mm 8.7” x 6.3” MAXIMUM PANEL THICKNESS 8 mm 0.3” STORAGE TEMPERATURE RANGE -40 °C to 85 °C -40 °F to 185 °F OPERATING TEMPERATURE RANGE -30 °C to 70 °C -40 °F to 185 °F HEATED DISPLAY VARIANT -40 °C to 70 °C -40 °F to 158 °F
Next Day Delivery Available on Certain Items (Order before 10:00)
Estimated Delivery: 2-4 days.












